Implementing a high-sensitivity cardiac troponin (hs-cTn) assay within a clinical pathway built into the electronic health record (EHR) was associated with shorter emergency department (ED) length of stay (LOS) for adults with chest pain, according to a quality improvement study published in JAMA Network Open.
The investigators noted that hs-cTn assays add implementation and workflow complexity and that earlier studies have reported mixed effects of hs-cTn adoption on ED LOS. Their intervention embedded a 0/1/3-hour troponin pathway in the Epic Care Path module, with automatic reflex ordering and automated result interpretation.
The retrospective study compared a period using a conventional fourth-generation cardiac troponin assay (June 2021 to March 2022) with a period using the fifth-generation hs-cTn pathway (June 2022 to March 2023) at 4 urban EDs in a single health system, covering 16,094 encounters. Mean ED LOS, the primary outcome, decreased from 6.18 to 5.64 hours, with reductions among both admitted and discharged patients. Among patients with serial troponin testing, time from the first troponin order to the second result fell from 5.16 to 3.18 hours in admitted patients and from 4.54 to 2.78 hours in discharged patients, even though the share of patients receiving a second troponin rose from 39.2% to 66.5%.
In patients with chronic kidney disease (estimated glomerular filtration rate below 60mL/min/1.73m²), mean LOS among admitted patients needing 2 or more troponin assays fell from 15.07 to 10.91 hours. Patients needing a single assay showed no significant difference, with or without kidney disease. Diagnoses of ST-segment elevation or non–ST-segment elevation myocardial infarction within 30 days were significantly more frequent with hs-cTn (2.42% vs 1.76%), while 30-day percutaneous coronary intervention and cardiology consultations did not differ.
The authors noted that the study was not powered to assess patient-centered outcomes such as missed myocardial infarction, readmissions, or mortality; that LOS was likely confounded by ED boarding; and that the multifaceted design prevented isolating the contributions of the assay, workflow redesign, and EHR automation.
Source: Jia LZ, Israelyan N, Shofer FS, et al. High-sensitivity troponin pathway and emergency department length of stay. JAMA Netw Open. 2026;9(11):e2642980. doi:10.1001/jamanetworkopen.2026.42980