Third degree AV block with complete atrioventricular dissociation
Among patients with atrioventricular (AV) block, left bundle-branch pacing (LBBP) reduced a composite of death from any cause, hospitalization for heart failure, or pacing-induced cardiomyopathy compared with right ventricular pacing (RVP), according to results of the OptimPacing trial published in the New England Journal of Medicine. The findings were presented as late-breaking science at the American Heart Association (AHA) Scientific Sessions 2026.
RVP is associated with cardiac dyssynchrony and left ventricular systolic dysfunction, the investigators noted. LBBP preserves left ventricular electrical and mechanical synchrony, but its clinical benefits relative to RVP in patients with AV block had remained unclear.
In the investigator-initiated, international, open-label trial, 702 patients with AV block were randomly assigned 1:1 to LBBP or RVP; 685 (342 LBBP, 343 RVP) were included in the modified intention-to-treat analysis. Mean age was 68.4 years, and 57.5% were men. At a prespecified interim analysis, the data monitoring committee recommended early termination of the trial. At a median follow-up of 35.1 months, a primary-outcome event had occurred in 16 patients in the LBBP group and 35 patients in the RVP group (4-year Kaplan-Meier cumulative incidences of 8.5% and 19.2%, respectively), a statistically significant difference.
Serious adverse events unrelated to implantation procedures occurred in 11.8% of patients who received LBBP and 9.3% of those who received RVP, a difference that was not statistically significant. According to the AHA release, no patients in the LBBP group developed pacing-induced cardiomyopathy, compared with 11.7% in the RVP group.
The investigators concluded that LBBP was superior to RVP in reducing the risk of the composite outcome in patients with AV block. Limitations cited in the AHA release included the possibility that early termination overestimated the benefit of LBBP and reduced the precision of estimates; that most participants had normal left ventricular ejection fraction at baseline, so the findings may not apply to people with reduced heart function; and that all LBBP procedures used the same type of lead.
Source: Qian Z, Jiang L, Hou X, et al. Left bundle-branch pacing versus right ventricular pacing for atrioventricular block. N Engl J Med. Published online November 8, 2026. doi:10.1056/NEJMoa2612972