The next-generation Amulet 360 left atrial appendage (LAA) occluder (Abbott) was associated with durable LAA closure and low rates of key clinical events through 1 year, according to results from the VERITAS study published in JACC: Cardiovascular Interventions.
According to the investigators, LAA occlusion is a stroke-prevention alternative for patients with atrial fibrillation (AF) who cannot tolerate long-term oral anticoagulation (OAC). The dual-seal device was redesigned with a more conformable lobe and a dual row of shorter stabilizing anchors. These changes were intended to make the device easier for operators to use while maintaining the LAA closure seen with the prior-generation device.
The prospective, single-arm, premarket study enrolled 458 patients with nonvalvular AF at 34 centers in the US, Canada, and Europe. Patients had a mean age of 74 years, 38.4% were female, and the mean CHA2DS2-VASc score was 4.1. Implantation was successful in 99.3% of patients. At 1 year, independent core laboratory imaging showed complete closure, with no peridevice leak, in 91.1% of patients assessed by transesophageal echocardiography (TEE) or cardiac CT and in 96.3% of those assessed by TEE alone. All 17 leaks larger than 3mm were detected on CT.
Through 1 year, all-cause mortality was 3.9% and cardiovascular mortality was 1.9%; no deaths were adjudicated as related to the device or procedure. Ischemic stroke occurred in 1.8% of patients, major bleeding in 6.6%, and pericardial effusion requiring intervention in 0.9%. No device embolization or systemic embolism occurred. Device-related thrombus was reported in 3.3% of patients, and clinically relevant thrombus, defined post hoc, in 0.4%. Most major bleeding events occurred early, while patients were mainly receiving dual antiplatelet therapy, and most were not procedure related. OAC use remained below 6%.
The investigators concluded that the results support the 1-year safety and effectiveness of the device. They noted that the study had no control group, so outcomes cannot be directly compared with other LAA occlusion devices or anticoagulants. In addition, procedures were performed by experienced operators, and longer follow-up is needed to assess the durability of stroke prevention.
Source: Lakkireddy D, Makkar A, Alkhouli M, et al. 1-Year safety and effectiveness of a next-generation dual-seal left atrial appendage occluder. JACC Cardiovasc Interv. Published online November 1, 2026. doi:10.1016/j.jcin.2026.10.023